RefurbUPS is your Trusted Source for New UPS solutions from Leading Manufacturers. RefurbUPS knowledge on the APC Symmetra PX UPS battery systems and assistance was invaluable during this crisis. Support of this caliber is all too rare.' Back-UPS ES 750 User's Manual: Download: Back-UPS 900 User's Manual: Download: Back-UPS 1250 User's.
Size:Download
English
APC
750/1000/1500 VA
100/120/230 Vac
2U
Uninterruptible Power Supply
Introduction
The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags, and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS provides continuous power from its internal battery until the utility line returns to safe levels or the battery is discharged.
1:INSTALLATION
Read the Safety Instruction sheet before installing the UPS.
Unpacking
Inspect the UPS upon receipt. APC designed robust packaging for your product. However, accidents and damage may occur during shipment. Notify the carrier and dealer if there is damage.
The packaging is recyclable; save it for reuse or dispose of it properly.
Check the package contents. The package contains the UPS, the front bezel, the rail kit, and a literature kit containing:
•Product documentation and safety information
•
•PowerChute®
•Serial and USB communication cables
•Two IEC jumper cables and one plug adaptor (230V models only)
The UPS is shipped with the battery disconnected.
Rail Installation
Install the rails following instructions in the rail kit.
Mounting rails are supplied for the standard
1
Positioning the UPS
Place the UPS where it will be used. The UPS is heavy. Select a location sturdy enough to handle the weight.
Do not operate the UPS where there is excessive dust or the temperature and humidity are outside the specified limits.
0º40ºC
PLACEMENT
Mounting the UPS in a Rack
The UPS is heavy. To lighten it, you may remove the battery before mounting the unit in the rack (Steps 1 and 2).
Step 3
Install the UPS at or near the bottom of the rack (Step 3).
Check to ensure the rack will not tip after installing the UPS into the rack.
2
Installing and Connecting the Battery and Attaching the Front Bezel
Connect battery plug to UPS. Tuck white battery cord into space above connector.
Connecting Equipment and Power to the UPS
100/120V Models
120V Model Only: Site wiring fault indicator
230V Models
3
1.Connect equipment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer draws significantly more power than other types of equipment and may overload the UPS.
2.Add any optional accessories to the
3.Using a power cord, plug the UPS into a
100V/120V models: The power cord is permanently attached to the rear panel of the UPS. The INPUT plug is a NEMA
230V models: The power cord is supplied by the customer. Connect ground leads to the TVSS screw (optional). To make the connection, loosen the screw and connect the surge suppression device’s ground lead. Tighten the screw to secure the lead.
4.Turn on all connected equipment. To use the UPS as a master ON/OFF switch, be sure all connected equipment is switched ON. The equipment will not be powered until the UPS is turned on.
5.To power up the UPS press the button on the front panel.
•The UPS charges its battery when it is connected to utility power. The battery charges to 90% capacity during the first four hours of normal operation. Do not expect full battery run capability during this initial charge period.
•120V Models: Check the site wiring fault LED located on the rear panel. It lights up if the UPS is plugged into an improperly wired utility power outlet. Refer toTroubleshooting in this manual.
6.For additional computer system security, install PowerChute®
BASICCONNECTORS
Use an APC supplied cable to connect to the Serial Port. DO NOT use a standard serial interface cable since it is incompatible with the UPS connector.
Both Serial and USB Ports are provided. They cannot be used simultaneously.
TVSS Screw The UPS features a transient voltage
When connecting grounding cable, disconnect the UPS from utility power.
4
Power On
Power Off
This LED illuminates to indicate the UPS is compensating for a high utility voltage.
This LED illuminates to indicate the UPS is compensating for a low utility voltage.
When the on battery power LED is lit the UPS is supplying battery power to the connected equipment. When on battery, the UPS sounds an
The LED illuminates and the UPS emits a sustained alarm tone when an overload condition occurs.
5
Replace Battery
Battery
Disconnected
Automatic
Manual
Failure of a battery
The replace battery LED flashes and short beep is emitted every two seconds to indicate the battery is disconnected.
The UPS performs a
During the
If the UPS fails the
Apc Es 750 Troubleshooting
Press and hold the button for a few seconds to initiate the
Full cracked version with GTA 5 torrent download link and GTA 5 direct download link given below. Grand Theft Auto 5 Free download. Download gta 4 torrent file.
On Battery Operation
The
Press the button (front panel) to silence the UPS alarm (for the current alarm only). If the utility power does not return, the UPS continues to supply power to the connected equipment until the battery is exhausted.
If PowerChute® is not being used you must manually save your files and turn off the computer before the UPS fully discharges the battery.
DETERMININGONBATTERYRUNTIME
UPS battery life differs based on usage and environment. It is recommended that the battery/batteries be changed once every three years. See the APC web site, www.apc.com, for on battery run times.
6
3:USERCONFIGURABLEITEMS
Apc Back Ups Es 750 User Manual
NOTE: SETTINGS ARE MADE THROUGH SUPPLIEDPOWERCHUTE SOFTWARE OR OPTIONALSMARTSLOT
Apc Back Ups 750 User Manual
ACCESSORY CARDS.
7
NOTE: SETTINGS ARE MADE THROUGH SUPPLIEDPOWERCHUTE SOFTWARE OR OPTIONALSMARTSLOT
Apc Back-ups Es 750 Manual
ACCESSORY CARDS.
Apc Back-ups Es 750 Manual
8
Comments are closed.
|
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |